Compare RUD VIP Grade 100 to RUD ICE Grade 120
| VIP Grade 100 & ICE Grade 120 - Working Load Limits (WLL) in tonnes | |||||||||||||
|
RUD - Lifting
Chain Dia. (mm) |
Single Leg Slings | Slings of 2, 3 or 4 Legs | Endless Slings | ||||||||||
Straight / Adj. Sling |
Reeved Sling |
![]() Straight Multileg Slings |
![]() Reeved Sling |
![]() Basket Sling |
Reeved |
||||||||
| 60° | 90° | 120° | 60° | 90° | 120° | ||||||||
| VIP 4 | 0.63 | 0.47 | 1.09 | 0.89 | 0.63 | 0.82 | 0.66 | 0.47 | 0.82 | 0.66 | 0.47 | 0.94 | |
| VIP 6 | 1.5 | 1.1 | 2.6 | 2.1 | 1.5 | 1.9 | 1.6 | 1.1 | 1.9 | 1.6 | 1.1 | 2.2 | |
| VIP 8 | 2.5 | 1.9 | 4.3 | 3.5 | 2.5 | 3.2 | 2.6 | 1.8 | 3.2 | 2.6 | 1.8 | 3.7 | |
| VIP 10 | 4.0 | 3.0 | 6.9 | 5.6 | 4.0 | 5.2 | 4.2 | 3.0 | 5.2 | 4.2 | 3.0 | 6.0 | |
| VIP 13 | 6.7 | 5.0 | 11.6 | 9.4 | 6.7 | 8.7 | 7.1 | 5.0 | 8.7 | 7.1 | 5.0 | 10.0 | |
| VIP 16 | 10.0 | 7.5 | 17.3 | 14.1 | 10.0 | 13.0 | 10.6 | 7.5 | 13.0 | 10.6 | 7.5 | 15.0 | |
| VIP 20 | 16.0 | 12..0 | 27.7 | 22.5 | 16.0 | 20.8 | 16.9 | 12.0 | 20.8 | 16.9 | 12.0 | 24.0 | |
| VIP 22 | 20.0 | 15.0 | 34.6 | 28.2 | 20.0 | 26.0 | 21.2 | 15.0 | 26.0 | 21.2 | 15.0 | 30.0 | |
| VIP 28 | 31.5 | 23.6 | 54.5 | 44.4 | 31.5 | 41.0 | 33.4 | 23.6 | 41.0 | 33.4 | 23.6 | 47.2 | |
| Load Factor |
1 | 0.75 | 1.73 | 1.41 | 1 | 1.3 | 1.06 | 0.75 | 1.3 | 1.06 | 0.75 | 1.5 | |
| ICE 6 | 1.8 | 1.3 | 3.1 | 2.5 | 1.8 | 2.3 | 1.9 | 1.3 | 2.3 | 1.9 | 1.3 | 2.7 | |
| ICE 8 | 3.0 | 2.2 | 5.2 | 4.2 | 3.0 | 3.9 | 3.2 | 2.2 | 3.9 | 3.2 | 2.2 | 4.5 | |
| ICE 10 | 5.0 | 3.7 | 8.6 | 7.0 | 5.0 | 6.5 | 5.3 | 3.7 | 6.5 | 5.3 | 3.7 | 7.5 | |
| ICE 13 | 8.0 | 6.0 | 13.8 | 11.3 | 8.0 | 10.4 | 8.5 | 6.0 | 10.4 | 8.5 | 6.0 | 12.0 | |
| ICE 16 | 12.5 | 9.4 | 21.6 | 17.6 | 12.5 | 16.2 | 13.2 | 9.4 | 16.2 | 13.2 | 9.4 | 18.7 | |
| Load Factor |
1 | 0.75 | 1.73 | 1.41 | 1 | 1.3 | 1.06 | 0.75 | 1.3 | 1.06 | 0.75 | 1.5 | |
| Temperature Considerations | When using Chain Slings at temperatures >200°C (392°F), the WLL has to be reduced. Working Load in % at temperatures of: |
||
| -60°C up to +200°C | 200°C up to 250°C | 250°C up to 300°C | |
| 100% | 90% | 60% | |
RUD ICE-120 Chain and Components conform fully to the requirements of EN 818 and 1677 for dynamic applications of 20,000 load cycles, with 50% over load.