Compare RUD VIP Grade 100 to RUD ICE Grade 120 VIP Grade 100 & ICE Grade 120 - Working Load Limits (WLL) in tonnes RUD - LiftingSystem.. Product #: Compare RUD VIP Grade 100 to RUD ICE Grade 120

Compare RUD VIP Grade 100 to RUD ICE Grade 120

VIP Grade 100 & ICE Grade 120 - Working Load Limits (WLL) in tonnes

RUD - Lifting
Systems in
Special Quality

vip ice

Chain Dia. (mm)

Single Leg Slings Slings of 2, 3 or 4 Legs Endless Slings
Straight SlingAdjustable Sling
Straight /
Adj. Sling
Reeved Sling
Reeved
Sling
Straight Multileg Slings
Straight Multileg Slings
Slings of 2, 3 or 4 Legs Reeved Sling
Reeved Sling
Endless Slings Basket Sling
Basket Sling

Endless Slings Reeved Sling

Reeved
Sling

60° 90° 120° 60° 90° 120°
VIP 4 0.63 0.47 1.09 0.89 0.63 0.82 0.66 0.47 0.82 0.66 0.47 0.94
VIP 6 1.5 1.1 2.6 2.1 1.5 1.9 1.6 1.1 1.9 1.6 1.1 2.2
VIP 8 2.5 1.9 4.3 3.5 2.5 3.2 2.6 1.8 3.2 2.6 1.8 3.7
VIP 10 4.0 3.0 6.9 5.6 4.0 5.2 4.2 3.0 5.2 4.2 3.0 6.0
VIP 13 6.7 5.0 11.6 9.4 6.7 8.7 7.1 5.0 8.7 7.1 5.0 10.0
VIP 16 10.0 7.5 17.3 14.1 10.0 13.0 10.6 7.5 13.0 10.6 7.5 15.0
VIP 20 16.0 12..0 27.7 22.5 16.0 20.8 16.9 12.0 20.8 16.9 12.0 24.0
VIP 22 20.0 15.0 34.6 28.2 20.0 26.0 21.2 15.0 26.0 21.2 15.0 30.0
VIP 28 31.5 23.6 54.5 44.4 31.5 41.0 33.4 23.6 41.0 33.4 23.6 47.2
Load
Factor
1 0.75 1.73 1.41 1 1.3 1.06 0.75 1.3 1.06 0.75 1.5
 
ICE 120 ICE 6 1.8 1.3 3.1 2.5 1.8 2.3 1.9 1.3 2.3 1.9 1.3 2.7
ICE 8 3.0 2.2 5.2 4.2 3.0 3.9 3.2 2.2 3.9 3.2 2.2 4.5
ICE 10 5.0 3.7 8.6 7.0 5.0 6.5 5.3 3.7 6.5 5.3 3.7 7.5
ICE 13 8.0 6.0 13.8 11.3 8.0 10.4 8.5 6.0 10.4 8.5 6.0 12.0
ICE 16 12.5 9.4 21.6 17.6 12.5 16.2 13.2 9.4 16.2 13.2 9.4 18.7
Load 
Factor
1 0.75 1.73 1.41 1 1.3 1.06 0.75 1.3 1.06 0.75 1.5
Temperature Considerations When using Chain Slings at temperatures >200°C (392°F), the WLL has to be reduced.
Working Load in % at temperatures of:
-60°C up to +200°C 200°C up to 250°C 250°C up to 300°C
100% 90% 60%

RUD ICE-120 Chain and Components conform fully to the requirements of EN 818 and 1677 for dynamic applications of 20,000 load cycles, with 50% over load.